I211(X)A
Single stage isolator, 5 MHz bandwidth, 132-174 MHz
- Temperature compensated
- Low insertion loss, high isolation
- High reliable design with top quality sub-components
- Each unit is optimized to customer specified frequency
X Load 0 No load (Circulator only) 2 30 watt load 3 60 watt load
Specifications
Frequency Range | 132 to 174 MHz |
Bandwidth | 5 MHz |
Connectors | N-Female |
Field Tunable | No |
VSWR (max) | 1.25 : 1 |
Insertion Loss (typ) Tx to Ant | 0.4 dB |
Insertion loss (max) Tx to Ant | 0.6 dB |
Average Input Power (max) | 125 W |
Isolation (typ) | 35 dB |
Isolation (min) | 25 dB |
I221(Y)A
Dual stage isolator, 5 MHz bandwidth, 132-174 MHz
- Temperature compensated
- Low insertion loss, high isolation
- High reliable design with top quality sub-components
- Each unit is optimized to customer specified frequency
Y Load
0 No load (Circulator only)
2 Dual load, 30 watt for load A and 30watt for load B
3 Dual load, 30 watt for load A and 60watt for load B
Specifications
Frequency Range | 132 to 174 MHz |
Bandwidth | 5 MHz |
Connectors | N-Female |
Field Tunable | No |
VSWR (max) | 1.25 : 1 |
Insertion Loss (typ) Tx to Ant | 0.7 dB |
Insertion loss (max) Tx to Ant | 1 dB |
Average Input Power (max) | 125 W |
Isolation (typ) | 75 dB |
Isolation (min) | 50 dB |
I311(X)A
Single stage isolator, 12 MHz bandwidth, 406-512 MHz
- Temperature compensated
- Low insertion loss, high isolation
- Reliable design with top quality sub-components
- Each unit is optimized to customer specified frequency
X Load
0 No load
2 30 watt
3 60 watt
Specifications
Frequency Range | 406 to 512 MHz |
Bandwidth | 12 MHz |
Connectors | N-Female |
Field Tunable | No |
VSWR (max) | 1.25 : 1 |
Insertion Loss (typ) Tx to Ant | 0.3 dB |
Insertion loss (max) Tx to Ant | 0.5 dB |
Average Input Power (max) | 125 W |
Isolation (typ) | 35 dB |
Isolation (min) | 25 dB |
I321(Y)A
Dual stage isolator, 12 MHz bandwidth, 406-512 MHz
- Temperature compensated
- Dual stage, high isolation, low insertion loss
- High reliable design with top quality sub-components
- Each unit is optimized to customer specified frequency
Y Load
0 No load
2 Dual load, 30 watt for load A and 30watt for load B 3 Dual load, 30 watt for load A 3 and 60watt for load B
Specifications
Frequency Range | 406 to 512 MHz |
Bandwidth | 12 MHz |
Connectors | N-Female |
Field Tunable | No |
VSWR (max) | 1.25 : 1 |
Insertion Loss (typ) Tx to Ant | 0.6 dB |
Insertion loss (max) Tx to Ant | 0.9 dB |
Average Input Power (max) | 125 W |
Isolation (typ) | 75 dB |
Isolation (min) | 50 dB |